FIRM-LOCK Volar Distal Radius Buttress Plate 2.4, juxta-articular (Item Code Left 90317 -Right 90316)
FIRM-LOCK Volar Distal Radius
Buttress Plate 2.4, juxta-articular
· 2.4mm
Locking Volar Juxta Articular Distal Radius Plate is pre-contoured with a complex bend
designed to fit the volar surface of the distal radius. Juxta-articular plates
may be used for more complex fractures. Placement is as distal as possible on
the radius. The locking holes in the head of the plate are angled 5° proximal
to the articular surface, to allow a more distal plate placement.
Undercuts on the bottom of the plate head
facilitate contouring of the plate to match the anatomy of the distal radius
and minimize the potential for soft tissue irritation
· Straight plates are contoured to fit
the radial column and have a notched tip that allows them to fit on the radial
styloid, adjacent to a temporary K-wire fixation.
· Locking Compression Plates (LCP) have
Combi holes which allow locking screw fixation in the threaded section or
compression in the non-threaded section of the hole.
· Locking screws offer a fixed-angle
construct to support the articular surface, reduce the need for bone graft, and
obtain fixation in osteoporotic bone.
Specifications · Plates available for Left and Right.· Plates available in Titanium. · Rounded edges minimize potential for
tendon adhesion.· Smaller plates and screws address
fracture fragments individually, with less overall implant bulk.
Indications 2.4mm Locking Volar Distal
Radius Buttress Plate is used or fixation of complex intra and extra-articular
fractures and osteotomies of the distal radius and other small bones.
https://www.facebook.com/ASCO.Medical.India
https://www.linkedin.com/company/ascomedical
https://www.instagram.com/asco_medical/
· 2.4mm
Locking Volar Juxta Articular Distal Radius Plate is pre-contoured with a complex bend
designed to fit the volar surface of the distal radius. Juxta-articular plates
may be used for more complex fractures. Placement is as distal as possible on
the radius. The locking holes in the head of the plate are angled 5° proximal
to the articular surface, to allow a more distal plate placement.
Undercuts on the bottom of the plate head
facilitate contouring of the plate to match the anatomy of the distal radius
and minimize the potential for soft tissue irritation
· Straight plates are contoured to fit
the radial column and have a notched tip that allows them to fit on the radial
styloid, adjacent to a temporary K-wire fixation.
· Locking Compression Plates (LCP) have
Combi holes which allow locking screw fixation in the threaded section or
compression in the non-threaded section of the hole.
· Locking screws offer a fixed-angle
construct to support the articular surface, reduce the need for bone graft, and
obtain fixation in osteoporotic bone.